Devices
SinoTrack setup
The ST-901 family speaks H02 and is configured by SMS.
SinoTrack ST-901, ST-906 and ST-915 speak the H02 protocol, port 5013. They are configured by SMS; the default password is 0000.
Commands
| Purpose | SMS |
|---|---|
| APN | 803 + password + + APN, for example 8030000 internet.vodafone.net |
| Server and port | 804 + password + + 109.199.113.161 5013, for example 8040000 109.199.113.161 5013 |
| Interval, seconds | 805 + password + + seconds, for example 8050000 10 |
| Time zone (Egypt) | 896 + password + E2, for example 8960000E2 |
The 804 command takes an IP address on most SinoTrack firmwares, so this one uses the number behind gps.lemurseye.com. If the server's address ever changes, LemursEye tells you and these units need the SMS again.
The unit replies SET OK to each. Wait a minute between commands.
Then in the console
Register the tracker with its device ID (printed as ID or IMEI on the unit) and protocol H02 / SinoTrack, assign it to the vehicle. ST-901 units report ignition on the ACC wire, so idle cost works once ACC is connected.