The ST-901 family speaks H02 and is configured by SMS.

SinoTrack ST-901, ST-906 and ST-915 speak the H02 protocol, port 5013. They are configured by SMS; the default password is 0000.

Commands

PurposeSMS
APN803 + password + + APN, for example 8030000 internet.vodafone.net
Server and port804 + password + + 109.199.113.161 5013, for example 8040000 109.199.113.161 5013
Interval, seconds805 + password + + seconds, for example 8050000 10
Time zone (Egypt)896 + password + E2, for example 8960000E2

The 804 command takes an IP address on most SinoTrack firmwares, so this one uses the number behind gps.lemurseye.com. If the server's address ever changes, LemursEye tells you and these units need the SMS again.

The unit replies SET OK to each. Wait a minute between commands.

Then in the console